{"id":1848,"date":"2018-01-03T21:34:29","date_gmt":"2018-01-03T13:34:29","guid":{"rendered":"http:\/\/www.jhouseconsulting.com\/?p=1848"},"modified":"2018-04-02T00:39:58","modified_gmt":"2018-04-01T16:39:58","slug":"repairing-the-hp-la2206x-monitors","status":"publish","type":"post","link":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/2018\/01\/03\/repairing-the-hp-la2206x-monitors-1848","title":{"rendered":"Repairing the HP LA2206x Monitors"},"content":{"rendered":"<p>Recently one of my customers was disposing some dead HP LA2206x monitors that were out of warranty. When I say \u201cdead\u201d, it just means that they were not powering on. As an electronics geek from the 80\u2019s I knew it was highly probable that this is just a simple power supply issue and well within my abilities to repair them. So I took them home and soon found that there is a common problem with the power supplies in these monitors where a diode is faulty.<\/p>\n<p>The following photo shows the ILPI-263 VA 491A013G1400R&nbsp;power supply unit with the D854 and D855 diodes highlighted.<!--more--><\/p>\n<p><a href=\"http:\/\/www.jhouseconsulting.com\/2018\/01\/03\/repairing-the-hp-la2206x-monitors-1848\/hp-la2206x-power-supply-unit\" rel=\"attachment wp-att-1850\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-1850\" title=\"HP LA2206x Power Supply Unit\" src=\"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-content\/uploads\/2018\/01\/HP-LA2206x-Power-Supply-Unit.png\" alt=\"HP LA2206x Power Supply Unit\" width=\"599\" height=\"375\" srcset=\"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-content\/uploads\/2018\/01\/HP-LA2206x-Power-Supply-Unit.png 748w, https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-content\/uploads\/2018\/01\/HP-LA2206x-Power-Supply-Unit-300x188.png 300w\" sizes=\"(max-width: 599px) 100vw, 599px\" \/><\/a><\/p>\n<p>One of the diodes will exhibit a complete short circuit. I found that due to the way the circuit is designed it\u2019s best to measure these correctly by removing a leg of each diode. Then you can easily determine which one is faulty by using the resistance (ohms) mode of a multimeter.<\/p>\n<p>Diodes tend to go short circuit from either over-heating or an over-voltage spike. It\u2019s difficult to say what may have caused this issue. I would expect that poor cooling and hot components will destroy the junction properties within a diode over time.<\/p>\n<p>Here\u2019s a couple of post where someone was repairing the same fault for a HP LA2306x monitor, which uses the same power supply unit, so it seems to be a common issue across these models:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.badcaps.net\/forum\/showthread.php?t=27243\" target=\"_blank\">https:\/\/www.badcaps.net\/forum\/showthread.php?t=27243<\/a><\/li>\n<li><a href=\"https:\/\/www.badcaps.net\/forum\/showthread.php?t=65900\" target=\"_blank\">https:\/\/www.badcaps.net\/forum\/showthread.php?t=65900<\/a><\/li>\n<\/ul>\n<p>All monitors I\u2019ve repaired to date use MBR5200 diodes, which are a 5A 200V Schottky Diode. Equivalents are SR5200, SB5200 and SR520.<\/p>\n<p>Nowadays you would typically purchase SR5200 diodes, and you can buy quantities of them off eBay for very little. If you know how to solder, you can disassemble, repair, and reassemble within about 20 minutes. These are still brilliant monitors to use for home office and kids computers, so well worth the small investment of my time.<\/p>\n<p><a href=\"http:\/\/www.jhouseconsulting.com\/2018\/01\/03\/repairing-the-hp-la2206x-monitors-1848\/sr5200-diodes\" rel=\"attachment wp-att-1849\"><img decoding=\"async\" class=\"aligncenter wp-image-1849\" title=\"SR5200 Diodes\" src=\"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-content\/uploads\/2018\/01\/SR5200-Diodes.png\" alt=\"SR5200 Diodes\" width=\"600\" height=\"450\" srcset=\"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-content\/uploads\/2018\/01\/SR5200-Diodes.png 640w, https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-content\/uploads\/2018\/01\/SR5200-Diodes-300x225.png 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<p>Happy repairing \ud83d\ude42<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Recently one of my customers was disposing some dead HP LA2206x monitors that were out of warranty. When I say \u201cdead\u201d, it just means that they were not powering on. As an electronics geek from the 80\u2019s I knew it was highly probable that this is just a simple power supply issue and well within &#8230; <a title=\"Repairing the HP LA2206x Monitors\" class=\"read-more\" href=\"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/2018\/01\/03\/repairing-the-hp-la2206x-monitors-1848\" aria-label=\"Read more about Repairing the HP LA2206x Monitors\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0,"footnotes":""},"categories":[514],"tags":[524,517,519,515,523,516,520,521,518,522],"class_list":["post-1848","post","type-post","status-publish","format-standard","hentry","category-electronics","tag-491a013g1400r","tag-dead","tag-diode","tag-hp","tag-ilpi-263","tag-la2206x","tag-la2306x","tag-mbr5200","tag-no-power","tag-sr5200"],"aioseo_notices":[],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/posts\/1848","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/comments?post=1848"}],"version-history":[{"count":5,"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/posts\/1848\/revisions"}],"predecessor-version":[{"id":1865,"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/posts\/1848\/revisions\/1865"}],"wp:attachment":[{"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/media?parent=1848"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/categories?post=1848"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jhouseconsulting.com\/jhouseconsulting\/wp-json\/wp\/v2\/tags?post=1848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}